Allow 24" copper strip to run down wall to sub floor. Fold copper at 90 degree angle at point where the wall meets the floor. Lay remainder of copper strip flat on subfloor. At least 2 inches of copper should contact the floor.

Cover copper strip on floor with conductive adhesive and new Staticworx™ ESD Flooring. For a cleaner installation, copper can be covered by wall base.

Finish installation by re-attaching AC outlet cover with screw removed in step 1. |
Any electrical outlet can be tested using a ground plug adaptor.

A Ground Plug Adapter is equipped with three indicating lights. The ONLY indication that is acceptable for Ground Plug Adapter use is with the two outer "CIRCUIT OK" lights energized, i.e., Lights #1 and #3 ON, Light #2 OFF.
*----------CIRCUIT OK---------*
Light #1
Yellow |
Light #2
Red |
Light #3
Clear |
If any other condition exists, do not use the receptacle or the Ground Plug Adapter until tested and approved by a qualified electrician. Examples of wiring defects are not limited to the conditions described below.
1. OPEN GROUND WIRE – The equipment grounding conductor is not complete.
2. REVERSE POLARITY - The hot and the neutral circuit conductors are reversed.
3. OPEN HOT WIRE - The hot circuit conductor is open from a blown fuse, tripped circuit breaker, switch off, broken wire, etc.
4. OPEN NEUTRAL WIRE - The neutral circuit conductor is open.
5. HOT AND GROUND REVERSED - The hot circuit conductor and the grounding conductor are reversed.
6. HOT ON NEUTRAL AND HOT OPEN - The hot circuit conductor is connected to neutral terminal and the hot terminal is unwired.
|
|